Fire Protection Sprinkler System Installation
Having thorough knowledge and experience in the installation of various fire sprinkler systems is critical for the safety and well-being of commercial building tenants as well as residential tenants. Experienced staff at GreenCity Plumber have solutions to your fire sprinkler problems including installation of dry pipe sprinkler systems, wet pipe sprinkler systems and anti-freeze loop systems.
If you are planning a complex renovation or require quick replacement of expired sprinkler heads in any of your properties, having the fire sprinkler system installed is half the battle. Obtaining an approved fire sprinkler plan and a fire sprinkler permit may seem excessive but in the event that there may be a fire in your property, your insurance company may want to verify that your fire sprinkler systems in your building are up to code and complied in every respect with the various fire code regulations.
We can assist you with getting sprinkler mechanical plans , fire sprinkler permits and expediting fire sprinkler plumbing inspections passed by the plumbing inspector whether your fire sprinkler plans call for pendant sprinkler heads, concealed pendant sprinkler heads, side wall mounted sprinkler heads, upright sprinkler heads or any combination thereof.
A prudent property manager always goes the extra mile to make sure that all fire sprinkler protection systems are cleared by the local plumbing inspector. This way there can be no excuse by the insurance company for not paying out the insured in the event of fire damage.
Various types of Sprinkler Systems that we install are:
- Wet Pipe Sprinkler Systems. By far, they are the most prevalent type of fire sprinkler system used today. High pressure water filled sprinkler pipes and closed sprinkler heads are installed in above freezing and heated area that are fire protected. Heat from a fire that will be close to a fire head will rupture the sprinkler head allowing water under high pressure to douse the fire. As the fire spreads, each head along the fire path will burst as the flames spread.
-
Dry Pipe Sprinkler Systems. This type of system is used in areas where the ambient temperatures can fall below freezing.Wet or dry pipe systems. GreenCity does them all.
Ambient temperatures below freezing include outside unprotected areas and areas where refrigeration equipment can cause the temperature to drop below freezing. Ahead of the dry valve, high pressure air fills the piping in the area to be protected. If a closed sprinkler head erupts, water is permitted to fill the dry void area, allowing water under high pressure to flood the fire area. As the fires spreads, each closed head along dry pipe system fire path will burst.
-
Antifreeze Loop Fire Systems
can be used in isolated areas that are subject to freezing. A check valve prevents mixing of glycol with high pressure water located in the main fire sprinkler system. When a fire occurs in these areas, glycol solutions first douse the fire and are backed up with high pressure water that streamsthrough the check valve. Sometimes check valves can develop leaks allowing clean pressurized water to mix and dilute the glycol solution thus allowing an Antifreeze Loop Fire System to freeze.
We can assist property managers by taking readings of glycol to determine if the glycol solution is satisfactory to prevent freeze ups or if the glycol loop has to be topped up. If it continually has to be topped up, this could be an indication that the check valve is leaking or that there is a leak in the system. If a system leak is detected, GreenCity Plumbers can trouble shoot for the leak. If it is determined that the leak is due to a leaking check valve, GreenCity Plumbers can install a new check valve. Depending on the size of the check valve it may be more prudent to install a refurbished valve rather than a brand new valve. GreenCity Plumbers can assist in determining which route to follow.
Besides these fire sprinkler systems there are other specialty types of fire sprinkler systems such as Preaction Sprinkler Systems and Foam Sprinkler Systems that can also be installed and serviced by GreenCity Plumbers if you have one of these systems.
When should a property owner replace sprinkler heads?
Where sprinkler heads are more than 50 years old, a representative sprinkler head sample from various areas that these expired heads are located should be tested by an accredited testing agency to determine if the sprinkler heads are up to today’s current standards. Prudent building owners often replace old sprinkler heads even if a representative sample passes the inspection test. The cost of replacement is small compared to old sprinkler heads that may not operate satisfactorily during a fire.
GreenCity Plumbing recommends that sprinkler heads known to be manufactured before 1920 be immediately replaced due to manufacturing methods that do not come close to complying to today’s sprinkler and fire prevention standards.
Our Gallery
Our professional Toronto plumbing team has worked with countless Toronto property managers and Toronto GTA commercial & industrial property owners.
View AllGet a Quote
The Rise of Green Architecture
May 13 2016 by GreenCity Plumber
Green architecture is vastly becoming a popular option to help the environment in a stylish way. This type of architecture promotes sustainable energy sources and…
View AllI received a letter from the City to install a backflow preventer. My building is 30 years old. Why do I have to install the backflow preventer after all this time?
It’s the law. City bylaw says that all industrial, commercial, institutional ICI properties and multi-residential properties of more than 4 units...
View AllWhat People Say
My basement toilet laundry tub constantly backed up whenever I washed clothes. GreenCity Plumbers snaked the drains and cleared the clog. Everything works smooth now. Wonderful to have my pipes cleaned by GreenCity Plumber.
- RS, Oakville, HomeownerBackflow preventer had to be installed in main 4” water main feeding our apartment building. GreenCity Plumbers worked very closely with us during the installation of the backflow preventer because water in the building had to be shut down for several hours. Although 200 families were inconvenienced, GreenCity pre-assembled all parts and backflow preventer for fast assembly prior to... - AB, Residential Property Manager, North York
Water was gushing from the floor at our carwash was due to huge water leak in the 6 in original iron water pipe installed more than 50 years ago. Without water, our carwash is out of business. GreenCity Plumbers quickly found the water leak 6 feet below existing concrete floor and temporarily sealed leak in a badly perforated pipe, allowing our carwash business to operate. In the meantime,... - RMB, Car Wash Owner, North York
Old steam boilers seemed more off than on. GreenCity replaced old boilers with new gas fired Fulton boilers. Building tenants now come to work without any expectations of “no heat” now that the new boilers are installed.
- RSW, Commercial Building Landlord, TorontoAfter major storms, lower level of our 60 year old industrial building always flooded. GreenCity Plumber determined cause of flooding was due to building storm water being connected to an internal plugged French drain system on our property. Green City recommended that property storm water be diverted directly to City storm water drains. GreenCity prepared engineered drawings for the... - AS, Industrial Processing Business , Scarborough